Chesapeake Times, Vol 18 | July 2024
Sometimes an improvement in SonarWiz takes a few releases to be fully realized. One such instance is the upgrade to the displayed range for SBP (sub-bottom) data. One of the areas of SonarWiz where we like to make improvements is the ability to import the data as is. Then allow the user to modify the data in post processing while preserving the original data so the adjustments can be performed multiple times so the user can get it just right without having to import the data multiple times. We have been replacing the processing of the data on import with post processing equivalents over the years. The transition from SonarWiz 5 to SonarWiz 6 marked a major transition where SonarWiz started storing floating point samples which allowed the user to make extensive color mapping adjustments in post processing. This article will focus on the upgrade of import based range truncation for the SBP data to the post processing displayed range adjustment the Side Scan Sonar data has enjoyed for many years.
Let’s start with the question: why do users need to adjust the range of the SBP data? Most of the time SBP data is collected at a close to optimal range for processing and review. This data does not benefit much from being able to adjust the range. The data that benefits the most is SBP data that was collected using an optimistic range which fell short of expectations. This data typically has a lot of blank or noisy data after the visible sediment. In order to allow the user to focus solely on the good data they remove the data that does not contain any useful information. Sometimes this region is small and sometimes it is really huge compared with the actual sediment data. The images below are a good example of this.
The image on the left has maybe 20% useful range and some of that is filled with multiple reflections from the seafloor. The image on the right, while having more watercolumn data, uses almost the full range for geologic acoustic returns.
For SonarWiz before V7.12.00, the range was adjusted by using the “Percent of range to map” import setting for SBP data (shown below in the screen shot). After import it could not be changed. The only solution to adjusting it after import was to delete the data in SonarWiz and import it again.
Starting with SonarWiz V7.12.00 we introduced the 2 layer sound velocity model for SBP data. In doing so, we removed the support for the import based “Percent of range to map”. Post processing displayed range was supposed to go in at this time however we were not able to revisit the work until SonarWiz V8.01.00 where we completed the transition. The SBP data’s range that is displayed and used throughout SonarWiz can be adjusted in the data’s properties shown below.
When the Display range property is changed from Full range to Specified range the user can set the displayed range to a value less than the full range of the data. This value entered can be any value however due to storage limitations in SonarWiz SBP data file the range is constrained to a value in 1% increments. In the below screenshot we have adjusted the displayed range to 30% however it worked out to be 26.25m. As you can see the maximum visible range has been reduced. This is carried through to all parts of SonarWiz including the exports. If the user decides that the display range needs to be adjusted it can be done without needing to reimport the data and the changes are visualized quickly.